Deflections of 45 to 55 mm during shock reduce the transmitted accelerations.
Flexible mountings for high loads MN 45
A load range of between 30 to 1,080 kg, depending on the different configuration and shock specification.
Download PDF catalog
Related products
These assemblies can withstand high compression loads (along Oz): up to1,000 tons/sq.meter.
They can absorb shear deformation (along Ox and Oy) of 50 to 100% of their height.
Cylindrical or annular type assemblies can also withstand torsional displacement around axis Oz.
In rotation around axes Oy and Ox, these mountings enable angular or low amplitude rotation errors (approximately 1°).
Download PDF catalog
Conical (fig. 1) or spherical (fig. 2) units are used to absorb very high axial loads of up to150 tons.
Angular movement around an axis (Oz in the case of the conical bearing) or a centre of rotation (O in the case of the spherical bearing) are in the order of ± 10°.
Download PDF catalog
These mountings were developed to handle small loads under large deflection (75 mm) and provide a low vibration transmission over a wide frequency range (up to 500 Hz).
The system developed provides this dual function effectively and without compromise.
Download PDF catalog
Laminated BUSHES use the same principle as other laminated bearings. Importance is primarily given to radial load capability along Ox and Oy which may be up to 100 tons.
Movement is allowed around an axis Oz or a centre of rotation O. Angular deflection is in the order of 30°.